Solution · P0
Modular Data Centres
Pre-fabricated 800V DC BUS modules — deploy in weeks, not months.
- 500 kW–5 MW
- Typical capacity
- Data centre developer / operator
- Primary buyer
- P0
- Priority tier
- Projected / Targeting
- Outcome confidence
The problem
Why this matters
Buyer pain first — architecture second. If the problem is not real, the stack is irrelevant.
Time-to-capacity for AI/edge infrastructure is bottlenecked by electrical fit-out.
Buyer jobs
- · Compress electrical fit-out time for modular capacity
- · Scale from kW blocks toward multi-MW campuses
Time-to-capacity for AI/edge infrastructure is bottlenecked by electrical fit-out.
Architecture notes
- · Prefabricated DC BUS modules as design-target packaging
- · Same platform layers as fixed sites — bus, meter, EMS
Architecture
How Joule Junction addresses it
Deployment scale 500 kW–5 MW. The solution traverses these energy-flow stages on the open DC platform.
Energy-flow path
Platform
Three layers. One stack.
Every solution runs on DC BUS, Metering, and Energy Management — the same open architecture at every scale.

DC BUS
The physical DC backbone. SST, BusWay, PCS, protection, and grid interface in one architecture — current flagship 800 V DC.
- Solid State Transformer (SST)
- DC BusWay
- Power Conversion System (PCS)

Metering
IEEE 2030.5-native data layer. Measurement at every point — grid edge, DC bus, load, charger.
- IEEE 2030.5 Smart Meters
- DC Energy Meters
- Sensors & Data Acquisition

Energy Management
Software that optimizes. The layer customers evaluate first.
- Forecasting
- Tariff optimisation
- Battery optimisation
Connected systems
What integrates on the bus
Systems designed to sit on the DC BUS for this solution.
Products
Platform building blocks
Hardware that shares energy-flow stages with this solution.
Solid State Transformer
MV AC → 800V DC in one step. No 50 Hz transformer.
Product →800V DC BusWay
The physical backbone. Plug-in DC distribution.
Product →Power Conversion System
Bidirectional AC ↔ DC conversion. Grid-forming capable.
Product →DC Meter
IEEE 2030.5-native measurement on the DC bus.
Product →Commercial outcome
What you are targeting
Outcomes below are design-target projections unless marked measured or customer-reported.
Projected / Targeting
Speed to capacity. Modular scaling from kW to MW.
More solutions
Related buyer paths
Grid Capacity
BESS + PCS + EMS orchestration to unlock capacity behind constrained grid connections.
Learn more →P0Fleet Charging
BESS + 800V DC BUS. All DC output voltages. Dynamic load management. V2G.
Learn more →P0Edge Data Centres
Compact 800V DC architecture for distributed edge deployments.
Learn more →Evaluating modular data centres for your project?
Talk with Joule Junction about site capacity, load profile, and architecture fit — platform first, products second.